Power Knowledge Center
Return to PEinfo.com Home Page
Contact us
Go to Customer Portal
Event Code Help (F0 - F65)
Order Status, Communications, and Follow-Ups
About Power Electronics® International
Drive Selection Help
PE® Product Categories
Installation Help
Drive Parameters
Troubleshooting and Product Assistance
Help with VFD Parameter Adjustment and Programming
Custom Panel Attachments
Event Code Help (F0 - F65)
Additonal Help with F1
Demonstration Videos
Product Service Center FAQ (Customer Care)
Using Ethernet/IP, Modbus TCP, or other protocols (Ultra models)
Back to home
Power Knowledge Center
Event Code Help (F0 - F65)
Order Status, Communications, and Follow-Ups
About Power Electronics® International
Drive Selection Help
PE® Product Categories
Installation Help
Drive Parameters
Troubleshooting and Product Assistance
Help with VFD Parameter Adjustment and Programming
Custom Panel Attachments
Event Code Help (F0 - F65)
Additonal Help with F1
Demonstration Videos
Product Service Center FAQ (Customer Care)
Using Ethernet/IP, Modbus TCP, or other protocols (Ultra models)
Event Code Help (F0 - F65)
What does F0 indicate?
F1 Code Help – 300% Over-Current
F2 Code Help – Motor Thermal Overload
F3 Code Help – Braking Resistor or Low Bus Voltage (Product Model Dependent)
F4 Code Help – Low Bus Voltage
F5 Code Help – Over Voltage
F6 or F7 Code Help – Auxiliary Input Trip (Programmable)
F8 Code Help – Parameters Out of Spec
F9 Code Help – CPU Error
F10 Code Help – Memory Error
F11 Code Help – Timer (Programmable)
F12 Code Help – Hardware Failure
F13 Code Help – External Overload Trip
F14 Code Help – Output Phase Loss
F17 Code Help – Encoder Tracking
F18 or F19 Code Help – Encoder Phase Loss
F20 Code Help – Heat Sink Temperature
F21 Code Help – Beginning Brake Test Not Passed
F22 Code Help – CPU
F23 Code Help – Brake Control Circuit Open
F24 Code Help – Output to Motor (T-Leads) Disconnected
F25 Code Help – Extra Encoder Pulses
F26 Code Help – Internal Brake Control Relay
F27 Code Help – Weight Limit Trip
F28 Code Help - Internal Power Supply
F33 Code Help – Tracking Error
F34 Code Help – Encoder Tracking During “Zip” Function
F35 or F36 Code Help – Encoder Speed Too Fast
F45 Code Help – Motion Test Failed / Binding
F46 Code Help – No Movement Detected
F47 Code Help – Encoder Pulse Count Too Low
F60, F61, F63, F64, and F65 - Industrial Networking Codes
Additonal Help with F1
F1 Code Help – 300% Over-Current
Does the drive trip out with an F1 code immediately (before moving the motor)?
Does an F1 occur when accelerating?
Does an F1 occur when decelerating?
Does F1 occur while traveling a constant speed, or when a certain speed is reached?
Does the drive ramp up in frequency, but the motor does not turn, and then an F1 occurs?
What else can cause F1?
See more