Explanation of "A" Parameters and handy reference chart for the MSM-R(P), CXR(P), MXU and MVU drives.
"A" Parameters Quick Reference Guide
For comprehensive details, please consult the specific manuals pertaining to your drive; the following chart only provides a summary of its key data.
Label | Models |
Name | Description | Range |
A1 |
CXR/MSM-R(P) |
Acceleration Rate 1 |
|
Adjustable from 0.1-30 sec (CXR/MSM-R(P)) |
MVU/MXU |
Acceleration 1 Time |
|
Adjustable from 0.1 - 6.0 sec | |
A2 | CXR/MSM-R(P) |
Acceleration Rate 2 |
|
Adjustable from 0.1-30 sec |
A3 |
CXR/MSM-R(P) |
Acceleration Mode |
|
Adjustable modes: 0-5 |
A4 |
CXR/MSM-R(P) |
Deceleration Rate 1 |
|
Adjustable from 0.1-30 sec |
MVU/MXU |
|
Adjustable from 0.1-60 sec | ||
A5 |
CXR/MSM-R(P) |
Deceleration Rate 2 |
|
Adjustable from 0.1-30 sec |
MVU/MXU |
Deceleration to Stop |
|
Adjustable from 0.1 - 60 sec | |
A6 |
CXR/MSM-R(P) |
Deceleration Rate 3 |
|
Adjustable from 0.1-30 secs |
MVU/MXU |
Deceleration when Reverse Plugging |
|
Adjustable from 0.1 - 60 sec |
|
A7 | CXR/MSM-R(P) |
Deceleration Mode |
|
Adjustable modes: 0-5 |
A8 | CXR/MSM-R(P) |
Voltage boost |
|
Adjustable from 1-30% of full line voltage |
A9 |
CXR/MSM-R(P) |
Operation Mode |
|
Adjustable Mode: 0 - 7 |
MVU/MXU |
|
Adjustable Modes: 0-6 | ||
A10 | CXR/MSM-R(P) |
Slip Compensation |
|
Adjustable from -10 to 10 Hz |
A12 |
CXR/MSM-R(P) |
Low Speed (FORward terminal, REVerse terminal) |
|
|
MVU/MXU |
Speed 1 |
|
Adjustable from 0.0 - 320 Hz | |
A13 |
CXR/MSM-R(P) |
Speed 2 (S2 terminal) |
|
|
MVU/MXU |
|
Adjustable from -1.00 to 320 Hz | ||
A14 |
CXR |
Speed 3 (S3 terminal) |
|
Adjustable from 1.0 -120 Hz |
MVU/MXU |
|
Adjustable from -1.00 to 320 Hz | ||
A15 |
CXR |
Speed 4 (S4 terminal) |
|
Adjustable from 1.0 -120 Hz |
MVU/MXU |
|
Adjustable from -1.00 to 320 Hz | ||
A16 |
CXR/MSM-R(P) |
Speed 5/Top Speed (S5) |
|
|
MVU/MXU |
Speed 5 |
|
Adjustable from -1.00 to 320 Hz | |
A17 |
CXR |
Analog Signal Upper Limit Frequency Setting |
|
Adjustable from 1.0 -120 Hz |
MVU/MXU |
Analog 1 Max Value |
|
Adjustable 0.0 - 320 Hz |
Notes on the MXU & MVU "A" Parameters:
- * What are "C" parameters?
- Many commonly used “C” parameters are mirrored in the “A” parameter group for quick access without the need for an unlock procedure. "C" parameters require are unlock procedure. Adjustments to the "A" parameters are typically sufficient for most applications.
- **Alternate "C" Parameters
- If the speeds set in C21-C25 are above the Speed Upper Limits or the maximum speeds,the actual speed will take on the lesser corresponding value. A negative value in C22-26 is “Off” (specific parameter notes available in manual).